Ophthalmology Calculator Crack + X64 1. Ophthalmology Calculator Crack was designed to be an easy to use professional application. The main features of the software are: 2. Adjustment of IOL power depending on corneal power and astigmatism; 3. Displaying the IOL calculation results with graphs and tables; 4. Utilizing the proprietary database of actual IOL constants; 5. Exploring hundreds of IOL constants by changing the lens constants one by one and observing the results; 6. Separating the haptic into five types; 7. The ability to read the IOL constants' meaning; 8. Text to speech feature; 9. Comprehensive guide to the IOL constants; 10. An advanced astigmatic change vector analysis tool. The Ophthalmology Calculator has been developed in accordance with the clinical and scientific information presented in the literature. The software also includes hundreds of IOL constants and complex IOLs. 1. Astigmatism: - The minimum axis angle of the Astigmatic change vector is set to 5°- the maximum is set to 180°. - The minimum axis tilt is set to 0° - the maximum is set to 360°. - The values that are above 180°, and the values that are below 0° are clamped to the values that were used for the calculation. - The values that are above or below 180° are set to the values that are specified in the dialog window. - The value for the total Astigmatic change is calculated as the square root of the sum of the squares of the values of Astigmatic change that are above the minimum axis angle. 2. Corneal Power: - The minimum corneal power is set to 1.70 D- the maximum is set to 23.0 D. - The values that are above or below 23.0 D are clamped to the values that were used for the calculation. - The value for the corneal power is calculated as the inverse of the square root of the sum of the squares of the values of corneal power that are above the minimum. 3. The IOL constants: - The minimum value for the power of the IOL is set to 2.00 D, and the maximum is set to 20.00 D. - The maximum value for the power of the IOL Ophthalmology Calculator Crack Download Latest 1. An easy to use and professional software package that contains two parts; IOL power calculator and astigmatic change vector analysis tool 2. Optimized constants for different IOLs and different eye shapes 3. Using the astigmatic change vector analysis tool, you can analyze the effect of a certain IOL and change in keratometry values on the estimated refraction power of the IOL. Features: 1. Each part has separate buttons. This allows you to save time by using the same buttons to calculate different variables Limitations: 1. Change of staphyloma is not an available feature in the software. 2. Only the display of the graphics is updated and no calculation is done while exporting the graphics to other applications Supported IOLs: 1. IOL powers SRK II, Hoffer Q, Haigis, Holladay I, Holladay 2, and SRK/T Supported Eye Shapes: 1. General eye shapes; emmetropia, hyperopia, and myopia Supported Laser Measurements: 1. Lasers that are commonly used with cataract surgery: EX29A, EX38A, EX60A, EX71A, EX83A, and EX88A Supported keratometric values: 1. Flat keratometry values: 44, 46, 48, 50, 52, 54, 56, 58, 60, 62, 64, 66, 68, 70, 72, 74, 76, 78, 80, 82, 84, 86, 88, 90, 92, 94, 96, 98, 100, 102, 104, 106, 108, 110, 112, 114, 116, 118, 120, 122, 124, 126, 128, 130, 132, 134, 136, 138, 140, 142, 144, 146, 148, 150, 152, 154, 156, 158, 160, 162, 164, 166, 168, 170, 172, 174, 176, 178, 180, 182, 184, 186, 188, 190, 192, 194, 196, 198, 200, 202, 204, 206, 208, 210, 212, 214, 216, 218, 220, 222, 224, 226, 228, 230, 232, 234, 236, 238, 240, 242, 244, 246, 248, 250, 252, 254, 256, 258, 260, 262, 264, 266, 268, 270, 272, 274, 276, 278, 280, 282, 284, 286, 288, 290, 292, 294, 296, 298, 300, 302, 304, 306, 308, 310, 312, 314, 316, 318, 320, 322, 324, 326, 328, 330, 332, 334, 336, 338, 340, 342, 344, 346, 348, 350, 352, 354, 356, 1a423ce670 Ophthalmology Calculator Crack + -IOL Power calculator: The IOL power calculations were performed using SRK/T, Holladay I, Haigis, Hoffer Q, and Binkhorst formulas. The power of each IOL was calculated from the measurements and the constants provided by the manufacturers of each IOL. The IOL constants are optimized in the software and are the same for all SRK/T, Holladay I, Haigis, and Binkhorst formulas, however are varied in Hoffer Q formula. SRK/T (Tscherning-Pentacam) - The coefficients for SRK/T formula and constants are optimized for the AL in the IOL. - The formula uses 12 variables, including the axial length AL, the cornea power C, the anterior chamber depth ACD, and the anterior curvature ARC. - The formula of SRK/T was selected for its accuracy and ease of use. - The optimized constants and variables are provided. - The software automatically does the calculation for each IOL power given the appropriate constants and variables. - The graph of the SRK/T regression is also provided - The IOL calculation was performed without pre-operative refraction, as the refractive correction is already included in the constants. - The program calculates the IOL power for all SRK/T, Holladay I, Haigis, and Binkhorst formulas. Hoffer Q (Ziemer Ophthalmic Systems AG) - The constants are optimized for the AL. - The formula uses 5 variables, including the axial length AL, the cornea power C, the anterior chamber depth ACD, and the anterior curvature ARC. - The constants and variables are provided. - The software automatically does the calculation for each IOL power given the appropriate constants and variables. - The graph of the Hoffer Q regression is also provided. - The IOL calculation was performed without pre-operative refraction, as the refractive correction is already included in the constants. - The program calculates the IOL power for all SRK/T, Hoffer Q, Haigis, and Binkhorst formulas. Haigis (Carl Zeiss Meditec) - The constants are optimized for the AL. - The formula uses 6 variables, including the axial length AL, the cornea power C, the anterior chamber depth ACD, and What's New in the Ophthalmology Calculator? System Requirements: Supported GPU: NVIDIA GeForce GTX 260 / Radeon HD 2800 / ATI Radeon HD2900 Series (256-bit) / NVIDIA GeForce GTX 470 / Radeon HD 4850 (512-bit) / ATI Radeon HD4870 / NVIDIA GeForce GTX 560 / Radeon HD 5850 / ATI Radeon HD 5800 Series (512-bit) NVIDIA GeForce GTX 670 / Radeon HD 7870 / ATI Radeon HD 7870 (512-bit) NVIDIA GeForce GTX 680 / Radeon HD 7970 / ATI Radeon HD 7970 (512-bit)
Related links:
Comments